WEDGE SOCKETS FOR CIVIL ENGINEERING
(wedge sockets for slurry wall grabs) with countersunk or overlapping pin
The specified load capacities refer only to the housings. The necessary safety factors according to DIN EN 16228 must be observed. The used ropes have to be adjusted accordingly.
Rope-Ø | Load capacity of the housing | Housing | a | b | c | d1 | e | g | h1 | h2 | |
---|---|---|---|---|---|---|---|---|---|---|---|
with a safety factor (SF) of | |||||||||||
SF 3 (kN) | SF 5 (kN) | Item-No. | |||||||||
22 | 125 | 70 | BBG 2224 00 000 000 | 41 | 97 | 178 | 58 | 64 | 123 | 360 | 154 |
24 | 125 | 70 | BBG 2224 00 000 000 | 41 | 97 | 178 | 58 | 64 | 123 | 360 | 154 |
26 | 190 | 110 | BBG 2628 00 000 000 | 48 | 113 | 270 | 68 | 75 | 144 | 420 | 180 |
28 | 190 | 110 | BBG 2628 00 000 000 | 48 | 113 | 270 | 68 | 75 | 144 | 420 | 180 |
30 | 240 | 140 | BBG 3032 00 000 000 | 53 | 127 | 238 | 77 | 85 | 165 | 480 | 206 |
32 | 240 | 140 | BBG 3032 00 000 000 | 53 | 127 | 238 | 77 | 85 | 165 | 480 | 206 |
34 | 310 | 180 | BBG 3436 00 000 000 | 53 | 137 | 231 | 78 | 89 | 158 | 517 | 231 |
36 | 310 | 180 | BBG 3436 00 000 000 | 53 | 137 | 231 | 78 | 89 | 158 | 517 | 231 |
Rope-Ø | Load capacity of the housing | Wedge | h3 | h4 | r | s | |
---|---|---|---|---|---|---|---|
with a safety factor (SF) of | |||||||
SF 3 (kN) | SF 5 (kN) | Item-No. | |||||
22 | 125 | 70 | BBK 0022 00 000 000 | 191 | 144 | 11.6 | 31 |
24 | 125 | 70 | BBK 0024 00 000 000 | 189.5 | 144 | 12.6 | 31 |
26 | 190 | 110 | BBK 0026 00 000 000 | 229 | 175 | 3.6 | 36 |
28 | 190 | 110 | BBK 0028 00 000 000 | 226 | 175 | 14.7 | 36 |
30 | 240 | 140 | BBK 0030 00 000 000 | 261 | 200 | 15.8 | 41 |
32 | 240 | 140 | BBK 0032 00 000 000 | 260 | 200 | 16.8 | 41 |
34 | 310 | 180 | BBK 0034 00 000 000 | 285 | 227 | 18 | 48 |
36 | 310 | 180 | BBK 0036 00 000 000 | 284 | 227 | 20 | 48 |
Rope-Ø | Load capacity of the housing | Pin (countersunk) | d2 | d3 | h5 | t | Wedge sockets complete | |
---|---|---|---|---|---|---|---|---|
with a safety factor (SF) of | with overlapping pin | |||||||
SF 3 (kN) | SF 5 (kN) | Item-No. | ||||||
22 | 125 | 70 | BBB 2224 00 000 000 | 48 | 58 | 95 | 30 | BBT 0022 KB 000 000 |
24 | 125 | 70 | BBB 2224 00 000 000 | 48 | 58 | 95 | 30 | BBT 0024 KB 000 000 |
26 | 190 | 110 | BBB 2628 00 000 000 | 55 | 65 | 111 | 35 | BBT 0026 KB 000 000 |
28 | 190 | 110 | BBB 2628 00 000 000 | 55 | 65 | 111 | 35 | BBT 0028 KB 000 000 |
30 | 240 | 140 | BBB 3032 00 000 000 | 62 | 74 | 125 | 35 | BBT 0030 KB 000 000 |
32 | 240 | 140 | BBB 3032 00 000 000 | 62 | 74 | 125 | 35 | BBT 0032 KB 000 000 |
34 | 310 | 180 | BBB 3436 00 000 000 | 62 | 74 | 133 | 35 | BBT 0034 KB 000 000 |
36 | 310 | 180 | BBB 3436 00 000 000 | 62 | 74 | 133 | 35 | BBT 0036 KB 000 000 |
Rope-Ø | Load capacity of the housing | Pin (overlapping) | d4 | h6 | m | n | Wedge sockets complete | |
---|---|---|---|---|---|---|---|---|
with a safety factor (SF) of | with overlapping pin | |||||||
SF 3 (kN) | SF 5 (kN) | Item-No. | ||||||
22 | 125 | 70 | - | - | - | - | - | - |
24 | 125 | 70 | - | - | - | - | - | - |
26 | 190 | 110 | BHB 2628 00 000 000 | 55 | 164 | 49 | 65 | BHT 0026 KB 000 000 |
28 | 190 | 110 | BHB 2628 00 000 000 | 55 | 164 | 49 | 65 | BHT 0028 KB 000 000 |
30 | 240 | 140 | BHB 3032 00 000 000 | 62 | 177 | 49 | 74 | BHT 0030 KB 000 000 |
32 | 240 | 140 | BHB 3032 00 000 000 | 62 | 177 | 49 | 74 | BHT 0032 KB 000 000 |
34 | 310 | 180 | BHB 3436 00 000 000 | 62 | 186 | 50 | 75 | BHT 0034 KB 000 000 |
36 | 310 | 180 | BHB 3436 00 000 000 | 62 | 186 | 50 | 75 | BHT 0036 KB 000 000 |
Further information
Please find certificates and instructions also in our media library section.
Subject to technical alternations