ROPE SUSPENSIONS WITH WEDGE SOCKETS ACC. TO DIN 43148
The wedge sockets acc. to DIN 43148 are not suitable for the use in areas liable to frost.
ATTENTION: The strength of the eye bolt must be in accordance to the strength of the wire rope.
Rope - ø | Main type A | d | L1 | L2 | Type FP | d2 | L4 | Type FP 2 | L5 | Type FP 3 | L6 |
---|---|---|---|---|---|---|---|---|---|---|---|
Item-no. | Item-no. | Item-no. | Item-no. | ||||||||
6 - 7 | KK2 0607 A0 300 148 | M12 | 430 | 300 | KK2 0607 F1 300 148 | 50 | 51 | KK2 0607 F2 300 148 | 79 | KK2 0607 F3 300 148 | 107 |
8 | KK2 0800 A0 300 148 | M12 | 430 | 300 | KK2 0800 F1 300 148 | 50 | 51 | KK2 0800 F2 300 148 | 79 | KK2 0800 F3 300 148 | 107 |
9 - 12 | KK2 0912 A0 300 148 | M12 | 430 | 300 | KK2 0912 F1 300 148 | 50 | 51 | KK2 0912 F2 300 148 | 79 | KK2 0912 F3 300 148 | 107 |
10 - 12 | KK2 1012 A0 300 148 | M16 | 440 | 300 | KK2 1012 F1 300 148 | 57 | 59 | KK2 1012 F2 300 148 | 87 | KK2 1012 F3 300 148 | 115 |
12 - 14 | KK2 1214 A0 300 148 | M16 | 440 | 300 | KK2 1214 F1 300 148 | 57 | 59 | KK2 1214 F2 300 148 | 87 | KK2 1214 F3 300 148 | 115 |
12 - 15 | KK2 1215 A0 400 148 | M20 | 590 | 400 | KK2 1215 F1 400 148 | 68 | 65 | KK2 1215 F2 400 148 | 93 | KK2 1215 F3 400 148 | 121 |
Further information
L2 =Standard lengths of the eye bolts are in mm, further lengths possible
When ordering, the required length of the eye bolts is to be incorporated into the item-no as per following example:
rope suspension type A for 9 mm rope diameter and an eye bolts length of 800 mm: KK2 0912 A0 800 148
Subject to technical alternations