ROPE SOCKETS FOR LIFTS ACC. TO DIN EN 13411-7
galvanized surface
ATTENTION: The strength of the eye bolt must be in accordance to the strength of the wire rope.
rope - ø | Rope socket housing | Rope wedge | Rope socket housing with wedge | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Item-no. | b | c | d | h1 | s | Item-no. | r1 | r2 | h2 | Item-no. | |
4 - 5 | SS1 0405 00 000 315 | 12 | 32 | 10 | 110 | 3 | K01 0405 00 000 315 | 2.5 | 9.5 | 68 | SS1 0405 K0 000 315 |
5 - 6,5 | SS1 0506 00 000 315 | 10 | 36 | 10 | 100 | 4 | K01 0506 00 000 315 | 3.25 | 9 | 58 | SS1 0506 K0 000 315 |
6 - 8 | SS1 0608 00 000 315 | 14 | 45 | 12 | 150 | 4 | K01 0608 00 000 315 | 4 | 12.5 | 92 | SS1 0608 K0 000 315 |
9 - 11 | SS1 0911 00 000 315 | 17 | 60 | 16 | 190 | 6 | K01 0911 00 000 315 | 5.5 | 16 | 117 | SS1 0911 K0 000 315 |
12 - 14 | SS1 1214 00 000 315 | 22 | 74 | 18 | 230 | 8 | K01 1214 00 000 315 | 7 | 19 | 141 | SS1 1214 K0 000 315 |
15 - 17 | SS1 1517 00 000 315 | 25 | 90 | 22 | 260 | 10 | K01 1517 00 000 315 | 8.5 | 23 | 162 | SS1 1517 K0 000 315 |
18 - 20 | SS1 1820 00 000 315 | 27 | 106 | 25 | 300 | 12 | K01 1820 00 000 315 | 10 | 26 | 186 | SS1 1820 K0 000 315 |
21 - 22* | SS1 2125 00 000 315 | 32 | 107 | 42.5 | 284 | 12 | K01 2125 00 000 315 | 13 | 30 | 182 | SS1 2125 K0 000 315 |
23 - 25*,** | SS1 2325 00 000 315 | 32 | 107 | 42.5 | 324 | 12 | K01 2125 00 000 315 | 13 | 30 | 182 | SS1 2325 K0 000 315 |
Further information
*cast design similar to DIN EN 13411-7
** longer strap for a better assembly of ropes with a diameter of 24/25 mm
Rope sockets acc. to DIN EN 13411-7 are not appropriate for ropes of more than 1770 N/mm² single wire strength
Please find certificates and instructions also in our media library section.
Subject to technical alternations
Contact Person
Certificates & Instructions for Use
Certificates for SS1 0405 00 000 315 NG 5 for rope-diameter 4 - 5 mm
- Instructions/Installation
- statical tensile NG5 4mm WSC Flex Core 1,3% nozn 2300 sZ PAWO geschm.
- fatigue test NG5 4mm WSC Flex Core 1,3% nozn 2300 sZ PAWO geschm.
- statical tensile NG5 5mm DRAKO6x19W 5,0 SFC 1570 UsZ
- fatigue test NG5 5mm DRAKO6x19W 5,0 SFC 1570 UsZ
- statical tensile NG5 5mm DRAKO6x19W 5,0 SFC 1770 UsZ
- fatigue test NG5 5mm DRAKO6x19W 5,0 FC 1770 B sZ
Certificates for SS1 0506 00 000 315 NG 6,5 for rope-diameter 5 - 6,5 mm
- Instructions/Installation
- statical tensile NG6,5 5mm 8x19s sZ IWRC
- fatigue test NG6,5 5mm 8x19s sZ IWRC
- statical tensile NG6,5 6mm HRS-BRUGG 6 9×8-PWRC 1770 U sZ
- statical tensile NG6,5 6mm BRUGG HRS-1 1770
- fatigue test NG6,5 6mm BRUGG HRS-1 1770
- statical tensile NG6,5 6mm DRAKO 6×19 W-WSC 1960 B Sz
- statical tensile NG6,5 6,5mm PAWO 819W
- fatigue test NG6,5 6,5mm PAWO 819W
- fatigue test NG6,5 6,5mm DRAKO 6×19 Warr. DIN 3059 FE-bk-1570 sZ
Certificates for SS1 0608 00 000 315 NG 8 for rope-diameter 6 - 8 mm
- Instructions/Installation
- statical tensile NG8 8mm DRAKO 250H 8,0 IWRC 1770 sZ
- fatigue test NG8 8mm DRAKO 250H 8,0 IWRC 1770 sZ
- statical tensile NG8 8mm DRAKO 300T 8,0 IWRC 1570 U sZ
- fatigue test NG8 8mm DRAKO 300T 8,0 IWRC 1570 U sZ
- statical tensile NG8 8mm Gustav Wolf 8xK19S-IWRC Power
- fatigue test NG8 8mm Gustav Wolf 8xK19S-IWRC Power Trac
- statical tensile NG8 8mm PAWO F7S
- fatigue test NG8 8mm PAWO F7S
- statical tensile NG8 8,1mm CTP-Brugg sZ IWRC 2800/2600
- fatigue test NG8 8,1mm CTP-Brugg sZ IWRC 2800/2600
Certificates for SS1 0911 00 000 315 NG11 for rope-diameter 9 - 11 mm
- Instructions/Installation
- statical tensile NG11 10mm DRAKO 250H 10,0 IWRC 1770 U sZ
- fatigue test NG11 10mm DRAKO 250H 10,0 IWRC 1770 U sZ
- statical tensile NG11 10mm Gustav Wolf 8xK19S-IWRC Power Trac
- fatigue test NG11 10mm Gustav Wolf 8xK19S-IWRC Power Trac
- statical tensile NG11 10mm PAWO F7S
- fatigue test NG11 10mm PAWO F7S
- statical tensile NG11 11mm DRAKO 300T 11,0 U 1570 sZ EGL
- fatigue test NG11 11mm DRAKO 300T 11,0 U 1570 sZ EGL
- fatigue test NG11 11mm Brugg Tragseil HRS-SES-1570 sZ
- statical tensile NG11 11mm PAWO 819W 1770
- fatigue test NG11 11mm PAWO 819W 1770
Certificates for SS1 1214 00 000 315 NG 14 for rope-diameter 12 - 14 mm
- Instructions/Installation
- statical tensile NG14 13mm DRAKO 250H 13,0 IWRC 1770 U sZ
- fatigue test NG14 13mm DRAKO 250H 13,0 IWRC 1770 U sZ
- statical tensile NG14 13mm DRAKO 300T 13,0 IWRC 1570 UsZ
- fatigue test NG14 13mm DRAKO 300T 13,0 IWRC 1570 UsZ
- statical tensile NG14 13mm PAWO F7S bk
- fatigue test NG14 13mm PAWO F7S bk
- statical tensile NG14 14mm DRAKO 250T 14,0 IWRC 1570 UsZ
- fatigue test NG14 14mm DRAKO 250T 14,0 IWRC 1570 UsZ
- fatigue test NG14 14mm DRAKO 300T
- statical tensile NG14 14mm PAWO 836 WS 1770
- fatigue test NG14 14mm PAWO 836 WS 1770
Certificates for SS1 1517 00 000 315 NG 17 for rope-diameter 15 - 17 mm
- Instructions/Installation
- statical tensile NG17 16mm DRAKO 300TX 16,0 IWRC 1960 U sZ
- fatigue test NG17 16mm DRAKO 300TX 16,0 IWRC 1960 U sZ
- statical tensile NG17 16mm PAWO F7S
- fatigue test NG17 16mm PAWO F7S
- statical tensile NG17 16mm DRAKO 250TPC 16,0 PWRC 1770
- fatigue test NG17 16mm DRAKO 250TPC 16,0 PWRC 1770